Beam-pro company have modern NDT equipment high technology with Calibration certificate from Qualified company third party according to international standard
Testing is performed by level I & II non-destructive testing technicians qualified and certified in accordance with the international SNT – TC – 1A program. Level 2 ASNT (American society for Non distractive testing).
Visual Inspection Testing
Structural welds are visually inspected to meet the applicable code . Beam also offers procedure and welders qualification tests to meet the applicable code.
Application
This can be applied for visual inspection of the following
Reference
Magnetic particle inspection Test.
Its portable magnetic particle testing equipment enables to detect ferromagnetic materials on the job site. Both visible and fluorescent methods are available.
EQUIPMENT AND MATERIALS
This procedure is intended for use with the following equipment and consumables or their equivalent.Magnaflux Y6 AC Yoke
Magnaflux WCP-1 White Contrast Paint
Magnaflux WCP-2 White Contrast Paint
Magnaflux 7HF Black Ink
Magnaflux SKC-NF Cleaner
Magnaflux SKC-C Cleaner
Magnaflux Dry Powder (Red, Yellow, or Grey colour)
Magnetic Field Indicators Type 1 Brass Finish
Dye penetration Test
Beam offers visible and fluorescent penetrant testing methods on both ferromagnetic and non-ferromagnetic materials.
MATERIALS
for use with the following consumables or their equivalent normally in aerosol containers.
Magnaflux SKC – NF Cleaner
Magnaflux SKL – HF Penetrant
Magnaflux SKD – NF Developer
Lint free cloth
Ultrasonic Testing (UT)
Beam can perform ultrasonic angle beam and straight beam testing in a variety of materials and welded connections.
Beam can also measure the wall thickness of pipes , pressure vessels, storage tanks, etc.
EQUIPMENT:
A pulse echo type instrument shall be used with capabilities of generating frequencies over the nominal range of 2 MHz to 4MHz.
The instrument shall be equipped with stepped gain control, calibrated in units of two (2) dB or less. Instruments operating at other frequencies may be used if equal or better sensitivity is demonstrated and documented.
Instruments using battery power shall be equipped with a low voltage-warning device.
Instruments shall meet the calibration requirements of the procedure
Instrument shall provide linear vertical presentation within ±5% of the full screen height at least 80% of the screen height.
Instrument shall be calibrated every (3) three months whichever is less.
Instrument shall utilize an amplitude control accurate over its useful range to ±20% of the amplitude ratio to allow measurement of indications beyond the linear range of vertical display on the screen